MSO3124V
DAQ, DSO, DVM, Frequency Counter, Logic Analyzer, Protocol Analyzer
Model |
Channels |
Record Length/ch
|
Vertical Resolution
|
Trigger
|
Electrical Validation
|
MSO3124E | 4 | 128 / 256 Mpts | 8 bits | Group I / I | --- |
MSO3124B | 4 | 128 / 256 Mpts | 8 bits | Group I, II, Bus I / I, II | --- |
MSO3124H | 4 | 128 / 256 Mpts | 16 bits | Group I, II, Bus I / I, II, III | --- |
MSO3124V | 4 | 128 / 256 Mpts | 16 bits | Group I, II, Bus I, II / I, II, III | I2C, I3C, SPI, UART,... |
Analog : 4CH, 1 GS/s S/R, 200 MHz bandwidth
Group I : Edge, Either, External, Falling, Rising, Video, Width
Group II: Runt, Pattern/ State, Timeout, Transition, Setup/ Hold, B-Trigger, B-Event, Window
Bus I : BiSS-C, CAN 2.0B/CAN FD, DALI, DP_Aux[1], I2C, I2S, LIN2.2, Modbus, Profibus, SENT, SPI, SVI2, UART UART(RS232), USB1.1, ...
Bus II : SVI3[2], SVID[3]
[1] Optional DP_Aux adapter needed.
[2] Upon request by user who is approved by AMD. SVI3 Bus Trigger / Decode are supported ONLY by MSO3124V.
[3] Upon request by user who has signed CNDA with Intel. SVID Bus Trigger / Decode are supported ONLY by MSO3124V.
Digital : 16CH, 2 GS/s Timing Analysis, 250 MHz State Analysis
Bus Trigger I:CAN2.0B/CAN FD, HID over I2C, I2C, I2S, LIN2.2, MIPI I3C 1.1, SENT, SPI, UART, USB PD 3.1, ...
Bus Trigger II:DALI, LPC, MDIO, Mini/Micro LED, MIPI RFFE 3, MIPI SPMI 2, PMBus, Profibus, SMBus, SVI2, ...
Bus Trigger III:eMMC 4.5, eSPI, MII, RGMII, RMII, SD 3.0 (SDIO 2.0), Serial Flash (SPI NAND), SVI3[2], SVID[3]
Protocol Analyzer I:CAN2.0B/CAN FD, HID over I2C, I2C, I2S, LIN2.2, MIPI I3C 1.1, SENT, SPI, UART, USB PD 3.1, ...
Protocol Analyzer II:DALI, MDIO, Mini/Micro LED, MIPI RFFE 3, Modbus, PMBus, Profibus, SMBus, USB1.1
Protocol Analyzer III:eSPI, MII, RGMII, RMII, SVI3[2], SVID[3]
Bus Decode:CAN 2.0B/CAN FD, DP_Aux[1], eSPI, I²C, I²S, MII, MIPI I3C 1.1, MIPI RFFE 3, MIPI SoundWire, SPI, SPI Flash, SVI3[2], SVID[3], UART, USB PD 3.1, ...(100+)
[1] Optional DP_Aux adapter needed.
[2] Upon request ONLY by users who have been authorized by AMD, SVI3 trigger & PA & Bus Decode supported by MSO3124H/V ONLY.
[3] Upon request ONLY by users who have signed CNDA with Intel, SVID trigger & PA & Bus Decode supported by MSO3124H/V ONLY.
Datasheet [PDF]
Logic Analyzer (LA) Mode
-
Capture digital waveforms and support bus decodes. Able to stack with a DSO to form as an MSO.
-
Provides multiple storage modes, users could select to have long time recording or precision acquisition.
-
Long Time Record: Transitional Storage VS Compressed Storage
For signal capture and analysis, usually require to record the signal for a long time. If the data is stored in a compressed way, it will cause your software to lag or even stop functioning when decompressing the data after it is sent back to the computer. Because PC memory size might insufficient for decompressed data size. To satisfy the requirement of smooth software operation and long-term recording without missing any data, the storage method adopted by the Acute analyzer is transitional storage rather than compression. After returning to the PC software, it doesn"t need to do the decompression. The decoded results can be displayed while the analysis is finished.
Measurement
More than 20 types of waveform measurements with customized threshold settings features, provides real-time update for vertical, time and channel to channel timing measurements with statistic features.
Time:Frequency, Period, ±Duty, ±Period, Rise/Fall Time, Delay, Phase
Vertical:VMax, VMin, VHigh, VLow, Vpp, VAmp, VMid, VMean, VRMS, ±Overshoot, Rise/Fall Preshoot
Counter:Edge Count, ±Pulse Count
Math:Add, Subtract, Multiple, Divide, XY, Absolute, Square Root, LogA, LnA, Exponential, Integral
Digital Voltmeter, DVM
Provides voltage root-mean-square, voltage average and frequency
counter function for the selected channel.
Measure 1 KHz, 2.5 Vpp square waveforms by the measurement function. | Measure 1 KHz, 2.5 Vpp square waveforms by the DVM function. |
Multiple Windows | Spectrum analysis (Fast Fourier transform, FFT) |
Multiple Window feature provides 4 display types (1x1, 2x1, 1x2, 2x2), which could displays 16 channels in maximum 4 different windows, provides clear waveform readability without lower the vertical resolution. | Apply FFT to the selected channel. |
|
Protocol Analyzer | Protocol Logger | Protocol Monitor |
Show real-time protocol data. | Like data logger, save massive data into SSD hard drive. | Like dash cameras, record protocol data by the device’s memory only. |
Application timing: massive protocol data with some idles in between. | Application timing: massive protocol data. | Application timing: trigger event only happens in very long time. |
|
Protocol Analyzer (PA) Mode
It is hardware decoding, may log protocol data very long time if without waveforms. Application timing: Preliminary protocol debug.
Digital & Analog Signals From MSO and External DSO From Other Vendors | |
MSO Enables Digital & Analog Channels (Using the same channels) | *[1]: Decode & Digital Signals;*[2]: MSO Analog Signals;*[3]: External DSO Signals |
Stack With Other Vendors of Oscilloscope
|
Flow chart bus triggers |
Power trigger for serial bus, 8-states flow chart setting with Counter/Timer |
Detail parameters for each states |
Analog waveform Input Sensitivity: 2mV/div to 10V/div; Max. Sampling Rate: 1GS/s @ 1Ch Can be used with High Voltage probe, Differential probe or Current probe. |
Digital waveform
Operation Range: ±30V Max. Timing Analysis: 2GS/s @ 8Ch |
Additional Information
Included Items:
- MSO3000 Main unit
- USB 3.0 Cable w/ Type C Adapter
- 4 x 250 MHz Probe
- Stack Cable
- LA POD
- Flying lead cables (LA20P)
- Grippers
- Zippered Carrying Bag
System Requirements:
- USB 3.0 port
- 8GB PC RAM (min), 16GB (recommended)
Supported Operating Systems:
- Windows 7/8/10/11 (64-bit)
- Linux Ubuntu (64-bit)*
- macOS*
* Free update by year end 2023