PDM Electrical Validation

PDM Electrical Validation


Performing PCM Electrical Validation with an oscilloscope ensures that the PDM signal meets its defined specifications. After an extended burn-in test, the electrical characteristics of the signal under test can be verified against the required specifications.

For protocol electrical validation, PDM protocol electrical characteristics are typically analyzed in two dimensions: vertical (voltage) and horizontal (time/phase).

To use this functionality effectively, first configure the oscilloscope with the appropriate protocol and specifications. Then, conduct repeated tests to generate an electrical characteristics report. The test parameters, including specifications and standards, will vary depending on the PDM baud rate.

Supported Models:

TS3124V (4-channel DSO)
TS3000 Specifications PDF MSO3124V (4-channel DSO + 16-channel LA) MSO3000 Specifications PDF

Overview Report


Reference Point Dialog & Waveform


HTML Report

PDM Electrical Validation Settings

1. General Settings: Channel sources, working voltage and speed

2. Decode / Trigger Settings:

 

3. Electrical Validation Parameter Settings: Frequency, Timing, Voltage limitation


4. Software EV control panel:

Stop Conditions:
Stop when acquired X times
Stop when Result Fail > X times

Information:
Select waveform

Save File:
Save as Html
Save as .MOW (Software format)

 

Electrical Validation Solution PDF