LA3136B+

$12,300.00

Logic Analyzer, Protocol Analyzer, Simple DSO

Compare

visamasteramerican expressdiscovershopify pay
SKU: LA3136B+
Availability : In Stock Pre order Out of stock
Categories: LA3000+ Series
Tags: LA3000+
Overview

⚠️ Note: The LA3000+ series of logic analyzers has sold out and is officially discontinued. Understanding the importance of this tool in your work, we're dedicated to facilitating a seamless transition.

📢We're thrilled to introduce the LA4000 series as its replacement, soon to be available on our website for your convenience.

Model
Channels
Bus Triggers
Protocol Analysis
LA3068E+ 68
I
I
LA3068B+
80
I, II
I, II
LA3136E+
136
I I
LA3136B+ 136 I, II I, II

Bus Triggers I  : I²C, MIPI I3C 1.1, SPI, UART (RS232), USB PD3.0

Bus Triggers II : eMMC5.1, eSPI, I²S, NAND Flash, SD3.0, Serial Flash, SVID, ...

Protocol Analysis I  : I²C, MIPI I3C 1.1, SPI, UART (RS232), USB PD3.0

Protocol Analysis II : CAN 2.0B/CAN-FD, BiSS-C, DALI, eSPI, I²S, LIN2.2, MDIO, PWM, SVID, ...

Bus Decode : CAN 2.0B/CAN-FD, DP_Aux, eMMC 5.1, I²C, MIPI I3C 1.1, Profibus, SD 3.0, SPI,SVID, SWD, UART (RS232), USB1.1, USB PD 3.0... 100+

    Logic Analyzer Mode

    Logic Analyzer (LA) Mode

    • MSO analog and digital channels can capture signals simultaneously.
      It can also stack an oscilloscope to compare digital and analog signals simultaneously, which is suitable for signal quality analysis.

      LA Storage Mode:
      Storage modeLong Time Record: Transitional Storage VS Compressed Storage
      For signal capture and analysis, usually require to record the signal for a long time. If the data is stored in a compressed way, it will cause your software to lag or even stop functioning when decompressing the data after it is sent back to the computer. Because PC memory size might insufficient for decompressed data size. To satisfy the requirement of smooth software operation and long-term recording without missing any data, the storage method adopted by the Acute analyzer is transitional storage rather than compression. After returning to the PC software, it doesn't need to do the decompression. The decoded results can be displayed while the analysis is finished. 

      Compressed en
      Transition en
      Software Main Window
      MSO3K LA en 01
      Analog & Digital waveformMSO3K LA en 02
      Auto Threshold Settings:
      1.Auto Detect ALL
      2.Auto Detect 2 en
      3. 
      Auto Detect 03 en

      Trigger Settings Window
      Trigger
      Multiple Protocols Analysis Simultaneously:
      Ex: I2C + USB PD3.0
      MultiProtocol

      MSO Stack With Other Vendors of Oscilloscope:

      (*Support DSO)SMBUS External DSO
      Stack DSO 1 Stack DSO 2

      MSO Enables Digital & Analog Channels (Using the same channels)
      SMBUS MSODigital & Analog Signals From MSO and External DSO From Other Vendors
      MSO DSO en*BUS_SMBUS: Decode & Digital Signals   *DSO: MSO Analog Signals   *Ext DSO: External DSO Signals

      Add Notes & Pictures in WaveformNote
      Power Management Protocols Solution for MSO
      Ex: PMBus(CH0 & CH1) & The Related Power Voltage(CH2) (*Digital CH0, CH1    Analog: CH2 )
      Power Management
    Protocol Analyzer Mode
    Protocol Analyzer (PA) Mode
    It is hardware decoding, may log protocol data very long time if without waveforms.
    Application timing: Preliminary protocol debug.

    PA Storage Mode:PA Storage Type
    Software Main Window:PA MODE

      Additional Information

      What's Included
      Included Items:
      • LA3000+ Main unit
      • LA-Pod
      • USB 3.0 Cable
      • Flying Lead Cable
      • BNC to MCX
      • Grippers
      • Adapter / Power cord
      Software & Support

      Manual:

      LA3000+ Manual

      Download

      Software:

      Acute USB 3.0 Driver

      Download

      Acute Logic Analyzer Main Program

      Download

      System Requirements
      System Requirements:
      • USB 3.0 port
      • 8GB PC RAM (min), 16GB (recommended)
      Supported Operating Systems:
      • Windows 7/8/10/11 (64-bit)