MSO2116B

$3,400.00

Logic Analyzer, Protocol Analyzer, Simple DSO

Compare

visamasteramerican expressdiscovershopify pay
SKU: MSO2116B
Availability : In Stock Pre order Out of stock
Categories: MSO2000 Series
Tags: MSO2000
Overview
Model
Channels
Sample Rate
Memory
Bus Trigger / Protocol Analyzer
Power Sequence Channels
MSO2008E
8 2GHz
2Gb I 8
MSO2116E
16 2GHz
4Gb
I, II 16
MSO2116B
16 2GHz
4Gb
I, II, III 16
MSO2216B
16 2GHz
8Gb
I, II, III, IV 16 (128 / 8 sets cascaded)

Datasheet [PDF]

Bus Decode : BiSS-C, CAN 2.0B/CAN FD, DP_Aux, eSPI, I²C, I²S, MIPI I3C, MII, Serial Flash, SPI, SVID, UART (RS232), USB PD 3, USB1.1, ... (100+)

Bus Trigger I : I2C, MIPI I3C 1.1, SPI, UART (RS232)
Bus Trigger II : BiSS-C, CAN2.0B/CAN FD, DP_Aux, HID over I2C, I2S, LIN2.2, MIPI SoundWire 1.2, SENT, USB PD 3
Bus Trigger III : DALI, LPC, MDIO, Mini/Micro LED, MIPI RFFE 3, MIPI SPMI 2.0, Modbus, PMBus, Profibus, SMBus, SVI2, USB1.1
Bus Trigger IV : eMMC 4.5, eSPI, MII, RGMII, RMII, SD 2.0 (SDIO 2.0), Serial Flash (SPI NAND), SVID

Protocol Analyzer I : I2C, MIPI I3C 1.1, SPI, UART (RS232)
Protocol Analyzer II : BiSS-C, CAN2.0B/CAN FD, DP_Aux, HID over I2C, I2S, LIN2.2, USB PD 3
Protocol Analyzer III : DALI, MDIO, MIPI RFFE 3, Modbus, PMBus, Profibus, PWM, SMBus, USB1.1
Protocol Analyzer IV : eSPI, MII, RGMII, RMII, SVID


Logic Analyzer Mode

Logic Analyzer (LA) Mode

  • MSO analog and digital channels can capture signals simultaneously.
    It can also stack an oscilloscope to compare digital and analog signals simultaneously, which is suitable for signal quality analysis.

    LA Storage Mode:
    Storage modeLong Time Record: Transitional Storage VS Compressed Storage
    For signal capture and analysis, usually require to record the signal for a long time. If the data is stored in a compressed way, it will cause your software to lag or even stop functioning when decompressing the data after it is sent back to the computer. Because PC memory size might insufficient for decompressed data size. To satisfy the requirement of smooth software operation and long-term recording without missing any data, the storage method adopted by the Acute analyzer is transitional storage rather than compression. After returning to the PC software, it doesn't need to do the decompression. The decoded results can be displayed while the analysis is finished. 

    Compressed en
    Transition en
    Software Main Window
    MSO3K LA en 01
    Analog & Digital waveformMSO3K LA en 02
    Auto Threshold Settings:
    1.Auto Detect ALL
    2.Auto Detect 2 en
    3. 
    Auto Detect 03 en

    Trigger Settings Window
    Trigger
    Multiple Protocols Analysis Simultaneously:
    Ex: I2C + USB PD3.0
    MultiProtocol

    MSO Stack With Other Vendors of Oscilloscope:

    (*Support DSO)SMBUS External DSO
    Stack DSO 1 Stack DSO 2

    MSO Enables Digital & Analog Channels (Using the same channels)
    SMBUS MSODigital & Analog Signals From MSO and External DSO From Other Vendors
    MSO DSO en*BUS_SMBUS: Decode & Digital Signals   *DSO: MSO Analog Signals   *Ext DSO: External DSO Signals

    Add Notes & Pictures in WaveformNote
    Power Management Protocols Solution for MSO
    Ex: PMBus(CH0 & CH1) & The Related Power Voltage(CH2) (*Digital CH0, CH1    Analog: CH2 )
    Power Management
Protocol Analyzer Mode
Protocol Analyzer (PA) Mode
It is hardware decoding, may log protocol data very long time if without waveforms.
Application timing: Preliminary protocol debug.

PA Storage Mode:PA Storage Type
Software Main Window:PA MODE
    Power Sequencing Verification
    Power Sequence Verification
    *This solution is only applicable to some MSO models.
    *MSO2000+ series supports cascading up to 8 devices(128 CH) for power sequence measurement.


    Power Sequence Report(HTML Format)

    Additional Information

    What's Included
    Included Items:
    • MSO2000 Main unit
    • USB 3.0 Cable
    • Lead Cable
    • Stack Cable
    • Grippers
    • Zippered Carrying Bag
    Software & Support

    Manual:

    MSO2000 Manual

    Download

    Software:

    Acute USB 3.0 Driver

    Download

    Acute MSO2000 Main Program

    Download

    Acute MSO2000 SDK - AqLaVISA

    Download

    System Requirements
    System Requirements:
    • USB 3.0 port
    • 8GB PC RAM (min), 16GB (recommended)
    Supported Operating Systems:
    • Windows 7/8/10/11 (64-bit)