Model |
Channels |
Sample Rate |
Memory |
Bus Trigger |
Protocol Analyzer |
TL4134E | 34 |
2GHz |
4Gb |
I | I |
TL4134B | 34 |
2GHz |
4Gb |
I, II | I, II |
TL4234B |
34 |
2GHz |
8Gb |
I, II, III | I, II, III |
Bus Trigger I : BiSS-C, CAN2.0B/CAN FD, DP_Aux, HID over I2C, I2C, I2S, LIN2.2, MIPI I3C 1.1, SPI, UART (RS232), USB PD 3.0
Bus Trigger II : DALI, LPC, Mini/Micro LED, PMBus, Profibus, SMBus, SVI2, USB1.1, ...
Bus Trigger III : eMMC 4.5, eSPI, MII, RGMII, RMII, NAND Flash, SD 3.0 (SDIO 2.0), ...
Protocol Analyzer I : BiSS-C, CAN2.0B/CAN FD, DP_Aux, HID over I2C, I2C, I2S, LIN2.2, MIPI I3C 1.1, SPI, UART (RS232), USB PD 3.0
Protocol Analyzer II : DALI, Mini/Micro LED, Profibus, SMBus, USB1.1, ...
Protocol Analyzer III : eSPI, MII, RGMII, RMII, ...
Bus Decode : CAN 2.0B/CAN FD, DP_Aux, eMMC 4.5, eSPI, I2C, I2S, MIPI DSI LP, MIPI I3C 1.1, NAND Flash, Profibus, SD 3.0 (SDIO 2.0), SPI, UART (RS232), ... 100+
Logic Analyzer (LA) Mode
-
MSO analog and digital channels can capture signals simultaneously.
LA Storage Mode:
It can also stack an oscilloscope to compare digital and analog signals simultaneously, which is suitable for signal quality analysis.
Long Time Record: Transitional Storage VS Compressed Storage
For signal capture and analysis, usually require to record the signal for a long time. If the data is stored in a compressed way, it will cause your software to lag or even stop functioning when decompressing the data after it is sent back to the computer. Because PC memory size might insufficient for decompressed data size. To satisfy the requirement of smooth software operation and long-term recording without missing any data, the storage method adopted by the Acute analyzer is transitional storage rather than compression. After returning to the PC software, it doesn't need to do the decompression. The decoded results can be displayed while the analysis is finished.
Software Main Window
Analog & Digital waveform
Auto Threshold Settings:
1.
2.
3.
Trigger Settings Window
Multiple Protocols Analysis Simultaneously:
Ex: I2C + USB PD3.0
MSO Stack With Other Vendors of Oscilloscope:
(*Support DSO)
MSO Enables Digital & Analog Channels (Using the same channels)
Digital & Analog Signals From MSO and External DSO From Other Vendors*BUS_SMBUS: Decode & Digital Signals *DSO: MSO Analog Signals *Ext DSO: External DSO Signals
Add Notes & Pictures in Waveform
Power Management Protocols Solution for MSO
Ex: PMBus(CH0 & CH1) & The Related Power Voltage(CH2) (*Digital CH0, CH1 Analog: CH2 )
It is hardware decoding, may log protocol data very long time if without waveforms.
Application timing: Preliminary protocol debug.
PA Storage Mode:
Software Main Window:
Additional Information
Included Items:
- TL4000 Main unit
- USB 3.0 Cable
- 18.5cm Lead Cable
- Stack Cable
- Grippers
- Zippered Carrying Case
- 8.5cm Lead Cable (TL4234B Only)
System Requirements:
- USB 3.0 port
- 8GB PC RAM (min), 16GB (recommended)
Supported Operating Systems:
- Windows 7/8/10/11 (64-bit)