TL4234B

$3,400.00

Analizador Lógico, Analizador de Protocolo, Osciloscopio Digital Sencillo DSO

Comparar

visamasteramerican expressdiscovershopify pay
SKU: TL4234B
Disponibilidad: En stock Reservar Agotado
Categorias: Serie TravelLogic
Etiquetas: TravelLogic
Descripción general
Modelo
Canales
Tasa de muestreo
Memoria
Disparador de bus
Analizador de protocolo
TL4134E 34
2GHz
4Gb
I I
TL4134B 34
2GHz
4Gb
I, II I, II
TL4234B
34
2GHz 8Gb
I, II, III I, II, III

Disparador de bus I  : BiSS-C, CAN2.0B/CAN FD, DP_Aux, HID over I2C, I2C, I2S, LIN2.2, MIPI I3C 1.1, SPI, UART (RS232), USB PD 3.0

Disparador de bus II : DALI, LPC, Mini/Micro LED, PMBus, Profibus, SMBus, SVI2, USB1.1, ...

Disparador de bus III : eMMC 4.5, eSPI, MII, RGMII, RMII, NAND Flash, SD 3.0 (SDIO 2.0), ...

Analizador de protocolo I  : BiSS-C, CAN2.0B/CAN FD, DP_Aux, HID over I2C, I2C, I2S, LIN2.2, MIPI I3C 1.1, SPI, UART (RS232), USB PD 3.0

Analizador de protocolo II : DALI, Mini/Micro LED, Profibus, SMBus, USB1.1, ...

Analizador de protocolo III : eSPI, MII, RGMII, RMII, ...

Decodificación de bus : CAN 2.0B/CAN FD, DP_Aux, eMMC 4.5, eSPI, I2C, I2S, MIPI DSI LP, MIPI I3C 1.1, NAND Flash, Profibus, SD 3.0 (SDIO 2.0), SPI, UART (RS232), ... 100+

Modo Analizador Lógico

Logic Analyzer (LA) Mode

  • Capture digital waveforms and support bus decodes. Able to stack with a DSO to form as an MSO.

  •  Provides multiple storage modes, users could select to have long time recording or precision acquisition.

    •  Long Time Record: Transitional Storage VS Compressed Storage

    For signal capture and analysis, usually require to record the signal for a long time. If the data is stored in a compressed way, it will cause your software to lag or even stop functioning when decompressing the data after it is sent back to the computer. Because PC memory size might insufficient for decompressed data size. To satisfy the requirement of smooth software operation and long-term recording without missing any data, the storage method adopted by the Acute analyzer is transitional storage rather than compression. After returning to the PC software, it doesn"t need to do the decompression. The decoded results can be displayed while the analysis is finished.

     

    Flow chart bus triggers

    Power trigger for serial bus, 8-states flow chart setting with Counter/Timer

    Detail parameters for each states

    Stack With Other Vendors of Oscilloscope
    Modo Analizador de Protocolos

    Protocol Analyzer (PA) Mode
    It is hardware decoding, may log protocol data very long time if without waveforms. Application timing: Preliminary protocol debug.

    Protocol Analyzer Protocol Logger Protocol Monitor
    Show real-time protocol data.
    Application timing: massive protocol data with some idles in between.
    Like data logger, save massive data into SSD hard drive.
    Application timing: massive protocol data.
    Like dash cameras, record protocol data by the device’s memory only.
    Application timing: trigger event only happens in very long time.

      Información Adicional

      ¿Qué está incluido?
      Elementos incluidos:
      • Unidad principal TL4000
      • Cable USB 3.0
      • Cable conductor de 18.5 cm
      • Cable conductor de 8.5 cm (solo TL4234B)
      • Cable de extensión
      • Pinzas
      • Funda de transporte con cremallera

      Software y Soporte

      Manual:

      Manual TL4000

      Descargar

      Software:

      Controlador USB 3.0 de Acute

      Descargar

      Programa Principal de Acute TL4000

      Descargar

      Acute TL4000 SDK - C/C++

      Descargar

      Acute TL4000 SDK - C#

      Descargar

      Requisitos del sistema
      Requisitos del sistema:
      • Puerto USB 3.0
      • 8 GB de RAM en PC como mínimo, se recomiendan 16 GB
      Sistemas operativos compatibles:
      • Windows 7/8/10/11 (64-bit)