LA-POD2

$1,100.00

Logic Analyzer, Protocol Analyzer, Simple DSO

Compare

visamasteramerican expressdiscovershopify pay
SKU: LA-POD 2
Availability : In Stock Pre order Discontinued
Tags: BusFinder
Overview

Logic Analyzer (LA) Mode:
Support eMMC 5.1, NAND Flash, SD 3.0 (SDIO 3.0), Serial Flash (SPI NAND), SPI Protocol trigger & 100+ Protocol decodes

• Capture digital waveforms and support bus decodes. Able to stack with a DSO to form as an MSO.

• Provides multiple storage modes, users could select to have long time recording or precision acquisition.

• Long Time Record: Transitional Storage VS Compressed Storage

For signal capture and analysis, usually require to record the signal for a long time. If the data is stored in a compressed way, it will cause your software to lag or even stop functioning when decompressing the data after it is sent back to the computer. Because PC memory size might insufficient for decompressed data size. To satisfy the requirement of smooth software operation and long-term recording without missing any data, the storage method adopted by the Acute analyzer is transitional storage rather than compression. After returning to the PC software, it doesn"t need to do the decompression. The decoded results can be displayed while the analysis is finished.


Parallel Clause Triggers
16-States parallel IF Clause settings for 128/64 channel value compare combined with AND/OR logic condition and 4 Timer/Counter conditions.

Flow chart bus triggers

 
Power trigger for serial bus, 8-states flow chart setting with Counter/Timer
Detail parameters for each states


Stack With Other Vendors of Oscilloscope

 

 

Add Notes & Pictures in Waveform

Protocol Analyzer (PA) Mode
It is hardware decoding, may log protocol data very long time if without waveforms. Application timing: Preliminary protocol debug.

Protocol Analyzer
Show real-time protocol data.
Application timing: massive protocol data with some idles in between.

Protocol Logger
Like data logger, save massive data into SSD hard drive.
Application timing: massive protocol data.

Protocol Monitor
Like dash cameras, record protocol data by the device’s memory only.
Application timing: trigger event only happens in very long time.

Logic Analyzer Mode

Logic Analyzer (LA) Mode

  • Capture digital waveforms and support bus decodes. Able to stack with a DSO to form as an MSO.

  •  Provides multiple storage modes, users could select to have long time recording or precision acquisition.

    •  Long Time Record: Transitional Storage VS Compressed Storage

    For signal capture and analysis, usually require to record the signal for a long time. If the data is stored in a compressed way, it will cause your software to lag or even stop functioning when decompressing the data after it is sent back to the computer. Because PC memory size might insufficient for decompressed data size. To satisfy the requirement of smooth software operation and long-term recording without missing any data, the storage method adopted by the Acute analyzer is transitional storage rather than compression. After returning to the PC software, it doesn"t need to do the decompression. The decoded results can be displayed while the analysis is finished.


    Measurement

     

    More than 20 types of waveform measurements with customized threshold settings features, provides real-time update for vertical, time and channel to channel timing measurements with statistic features.
    Time:Frequency, Period, ±Duty, ±Period, Rise/Fall Time, Delay, Phase
    Vertical:VMax, VMin, VHigh, VLow, Vpp, VAmp, VMid, VMean, VRMS, ±Overshoot, Rise/Fall Preshoot
    Counter:Edge Count, ±Pulse Count
    Math:Add, Subtract, Multiple, Divide, XY, Absolute, Square Root, LogA, LnA, Exponential, Integral

     

    Digital Voltmeter, DVM
    Provides voltage root-mean-square, voltage average and frequency
    counter function for the selected channel.

    Measure 1 KHz, 2.5 Vpp square waveforms by the measurement function. Measure 1 KHz, 2.5 Vpp square waveforms by the DVM function.

    Multiple Windows Spectrum analysis (Fast Fourier transform, FFT)
    Multiple Window feature provides 4 display types (1x1, 2x1, 1x2, 2x2), which could displays 16 channels in maximum 4 different windows, provides clear waveform readability without lower the vertical resolution. Apply FFT to the selected channel.
       
    Protocol Analyzer Protocol Logger Protocol Monitor
    Show real-time protocol data. Like data logger, save massive data into SSD hard drive. Like dash cameras, record protocol data by the device’s memory only.
    Application timing: massive protocol data with some idles in between. Application timing: massive protocol data. Application timing: trigger event only happens in very long time.
      Protocol Analyzer Mode

      Protocol Analyzer (PA) Mode
      It is hardware decoding, may log protocol data very long time if without waveforms. Application timing: Preliminary protocol debug.

      Digital & Analog Signals From MSO and External DSO From Other Vendors
      MSO Enables Digital & Analog Channels (Using the same channels) *[1]: Decode & Digital Signals*[2]: MSO Analog Signals*[3]: External DSO Signals
      Stack With Other Vendors of Oscilloscope

      Flow chart bus triggers

      Power trigger for serial bus, 8-states flow chart setting with Counter/Timer

      Detail parameters for each states

      Analog waveform
      Input Sensitivity: 2mV/div to 10V/div; Max. Sampling Rate: 1GS/s @ 1Ch
      Can be used with High Voltage probe, Differential probe or Current probe.

      Digital waveform
      Operation Range: ±30V
      Max. Timing Analysis: 2GS/s @ 8Ch

      Additional Information

      What's Included
      Included Items:
      • Cables / Probes specific to the selected protocol -- see description above for details.

      Note: Requires a BusFinder to form a complete solution.

      Software & Support

      Manual:

      Acute BusFinder Manual

      Download

      Software:

      Acute USB 3.0 Driver

      Download

      Acute BusFinder Main Program

      Download

      System Requirements
      System Requirements:
      • USB 3.0 port
      • 8GB PC RAM (min), 16GB (recommended)
      Supported Operating Systems:
      • Windows 7/8/10/11 (64-bit)