Overview
Model |
Channels |
Module |
Protocol Decode |
Protocol Trigger |
TB3016F | 19 |
I |
70+ |
I |
TB3016E |
19 |
I, II |
70+ | I, II |
TB3016B | 25 |
I, II, III |
70+ |
I, II, III |
Protocol Decode: CAN FD, DALI2.0, DP_Aux, I²C, I²S, LIN2.2, PMBus, PWM, SMBus, SPI, MIPI I3C 1.1, UART, USB PD 3, ... (70+ decodes)
Module I: I²C, RS232, SPI
Module II: HID over I²C, I²S, LIN2.2, MDIO, PMBus, SMBus, USB1.1
Module III: BiSS-C, CAN2.0B, CAN-FD, DALI2.0, Modbus, Profibus, RS422, RS485, USB PD 3, ...
- Differential channels: 2 (CAN2.0B/CAN-FD), 4 (RS422/485)
- Stackable with Acute TravelScope DSO to form an MSO
- Isolated Ground: CAN2.0B/CAN-FD, RS485 (Safety Isolation >1000Vrms)
Logic Analyzer Mode
Logic Analyzer (LA) Mode
-
MSO analog and digital channels can capture signals simultaneously.
LA Storage Mode:
It can also stack an oscilloscope to compare digital and analog signals simultaneously, which is suitable for signal quality analysis.
Long Time Record: Transitional Storage VS Compressed Storage
For signal capture and analysis, usually require to record the signal for a long time. If the data is stored in a compressed way, it will cause your software to lag or even stop functioning when decompressing the data after it is sent back to the computer. Because PC memory size might insufficient for decompressed data size. To satisfy the requirement of smooth software operation and long-term recording without missing any data, the storage method adopted by the Acute analyzer is transitional storage rather than compression. After returning to the PC software, it doesn't need to do the decompression. The decoded results can be displayed while the analysis is finished.
Software Main Window
Analog & Digital waveform
Auto Threshold Settings:
1.
2.
3.
Trigger Settings Window
Multiple Protocols Analysis Simultaneously:
Ex: I2C + USB PD3.0
MSO Stack With Other Vendors of Oscilloscope:
(*Support DSO)
MSO Enables Digital & Analog Channels (Using the same channels)
Digital & Analog Signals From MSO and External DSO From Other Vendors*BUS_SMBUS: Decode & Digital Signals *DSO: MSO Analog Signals *Ext DSO: External DSO Signals
Add Notes & Pictures in Waveform
Power Management Protocols Solution for MSO
Ex: PMBus(CH0 & CH1) & The Related Power Voltage(CH2) (*Digital CH0, CH1 Analog: CH2 )
Protocol Analyzer Mode
Protocol Analyzer (PA) Mode
It is hardware decoding, may log protocol data very long time if without waveforms.
Application timing: Preliminary protocol debug.
PA Storage Mode:
Software Main Window:
It is hardware decoding, may log protocol data very long time if without waveforms.
Application timing: Preliminary protocol debug.
PA Storage Mode:
Software Main Window:
TB3016E
$420.00
Additional Information
What's Included
Included Items:
- TB3000 Main unit
- USB 3.0 Cable
- Lead Cable
- Grippers
- Terminal Block (TB3016B Only)
- D-Sub Connector (TB3016B Only)
System Requirements
System Requirements:
- USB 3.0 port
- 8GB PC RAM (min), 16GB (recommended)
Supported Operating Systems:
- Windows 7/8/10/11 (64-bit)