LA3068B+

$12,294.00

Logic Analyzer, Protocol Analyzer, Simple DSO

Compare

visamasteramerican expressdiscovershopify pay
SKU: LA3068B+
Availability : In Stock Pre order Out of stock
Categories: LA3000+ Series
Tags: LA3000+
Overview

⚠️ Note: The LA3000+ series of logic analyzers has sold out and is officially discontinued. Understanding the importance of this tool in your work, we're dedicated to facilitating a seamless transition.

📢We're thrilled to introduce the LA4000 series as its replacement, soon to be available on our website for your convenience.

Model
Channels
Bus Triggers
Protocol Analysis
LA3068E+ 68
I
I
LA3068B+
68
I, II
I, II
LA3136E+
136
I I
LA3136B+ 136 I, II I, II

Bus Triggers I  : I²C, MIPI I3C 1.1, SPI, UART (RS232), USB PD3.0

Bus Triggers II : eMMC5.1, eSPI, I²S, NAND Flash, SD3.0, Serial Flash, SVID, ...

Protocol Analysis I  : I²C, MIPI I3C 1.1, SPI, UART (RS232), USB PD3.0

Protocol Analysis II : CAN 2.0B/CAN-FD, BiSS-C, DALI, eSPI, I²S, LIN2.2, MDIO, PWM, SVID, ...

Bus Decode : CAN 2.0B/CAN-FD, DP_Aux, eMMC 5.1, I²C, MIPI I3C 1.1, Profibus, SD 3.0, SPI,SVID, SWD, UART (RS232), USB1.1, USB PD 3.0... 100+

    Logic Analyzer Mode

    Logic Analyzer (LA) Mode

    • Capture digital waveforms and support bus decodes. Able to stack with a DSO to form as an MSO.

    •  Provides multiple storage modes, users could select to have long time recording or precision acquisition.

      •  Long Time Record: Transitional Storage VS Compressed Storage

      For signal capture and analysis, usually require to record the signal for a long time. If the data is stored in a compressed way, it will cause your software to lag or even stop functioning when decompressing the data after it is sent back to the computer. Because PC memory size might insufficient for decompressed data size. To satisfy the requirement of smooth software operation and long-term recording without missing any data, the storage method adopted by the Acute analyzer is transitional storage rather than compression. After returning to the PC software, it doesn"t need to do the decompression. The decoded results can be displayed while the analysis is finished.


      Measurement

       

      More than 20 types of waveform measurements with customized threshold settings features, provides real-time update for vertical, time and channel to channel timing measurements with statistic features.
      Time:Frequency, Period, ±Duty, ±Period, Rise/Fall Time, Delay, Phase
      Vertical:VMax, VMin, VHigh, VLow, Vpp, VAmp, VMid, VMean, VRMS, ±Overshoot, Rise/Fall Preshoot
      Counter:Edge Count, ±Pulse Count
      Math:Add, Subtract, Multiple, Divide, XY, Absolute, Square Root, LogA, LnA, Exponential, Integral

       

      Digital Voltmeter, DVM
      Provides voltage root-mean-square, voltage average and frequency
      counter function for the selected channel.

      Measure 1 KHz, 2.5 Vpp square waveforms by the measurement function. Measure 1 KHz, 2.5 Vpp square waveforms by the DVM function.

      Multiple Windows Spectrum analysis (Fast Fourier transform, FFT)
      Multiple Window feature provides 4 display types (1x1, 2x1, 1x2, 2x2), which could displays 16 channels in maximum 4 different windows, provides clear waveform readability without lower the vertical resolution. Apply FFT to the selected channel.
         
      Protocol Analyzer Protocol Logger Protocol Monitor
      Show real-time protocol data. Like data logger, save massive data into SSD hard drive. Like dash cameras, record protocol data by the device’s memory only.
      Application timing: massive protocol data with some idles in between. Application timing: massive protocol data. Application timing: trigger event only happens in very long time.
        Protocol Analyzer Mode

        Protocol Analyzer (PA) Mode
        It is hardware decoding, may log protocol data very long time if without waveforms. Application timing: Preliminary protocol debug.

        Digital & Analog Signals From MSO and External DSO From Other Vendors
        MSO Enables Digital & Analog Channels (Using the same channels) *[1]: Decode & Digital Signals*[2]: MSO Analog Signals*[3]: External DSO Signals
        Stack With Other Vendors of Oscilloscope

        Flow chart bus triggers

        Power trigger for serial bus, 8-states flow chart setting with Counter/Timer

        Detail parameters for each states

        Analog waveform
        Input Sensitivity: 2mV/div to 10V/div; Max. Sampling Rate: 1GS/s @ 1Ch
        Can be used with High Voltage probe, Differential probe or Current probe.

        Digital waveform
        Operation Range: ±30V
        Max. Timing Analysis: 2GS/s @ 8Ch

        Additional Information

        What's Included
        Included Items:
        • LA3000+ Main unit
        • LA-Pod
        • USB 3.0 Cable
        • Flying Lead Cable
        • BNC to MCX
        • Grippers
        • Adapter / Power cord
        Software & Support

        Manual:

        LA3000+ Manual

        Download

        Software:

        Acute USB 3.0 Driver

        Download

        Acute Logic Analyzer Main Program

        Download

        System Requirements
        System Requirements:
        • USB 3.0 port
        • 8GB PC RAM (min), 16GB (recommended)
        Supported Operating Systems:
        • Windows 7/8/10/11 (64-bit)