MSO2008E
Analizador Lógico, Analizador de Protocolo, Osciloscopio Digital Sencillo DSO
Modelo |
Canales |
Tasa de muestreo |
Memoria |
Disparador de Bus / Analizador de protocolo |
Canales de secuencia de energía |
MSO2008E |
8 | 2GHz |
2Gb | I | 8 |
MSO2116E |
16 | 2GHz |
4Gb |
I, II | 16 |
MSO2116B |
16 | 2GHz |
4Gb |
I, II, III | 16 |
MSO2216B |
16 | 2GHz |
8Gb |
I, II, III, IV | 16 (128 / 8 conjuntos en cascada) |
Datasheet [PDF]
Decodificación de Bus : BiSS-C, CAN 2.0B/CAN FD, DP_Aux, eSPI, I²C, I²S, MIPI I3C, MII, Serial Flash, SPI, SVID, UART (RS232), USB PD 3, USB1.1, ... (100+)
Disparador de Bus I : I2C, MIPI I3C 1.1, SPI, UART (RS232)
Disparador de Bus II : BiSS-C, CAN2.0B/CAN FD, DP_Aux, HID over I2C, I2S, LIN2.2, MIPI SoundWire 1.2, SENT, USB PD 3
Disparador de Bus III : DALI, LPC, MDIO, Mini/Micro LED, MIPI RFFE 3, MIPI SPMI 2.0, Modbus, PMBus, Profibus, SMBus, SVI2, USB1.1
Disparador de Bus IV : eMMC 4.5, eSPI, MII, RGMII, RMII, SD 2.0 (SDIO 2.0), Serial Flash (SPI NAND), SVID
Analizador de Protocolo I : I2C, MIPI I3C 1.1, SPI, UART (RS232)
Analizador de Protocolo II : BiSS-C, CAN2.0B/CAN FD, DP_Aux, HID over I2C, I2S, LIN2.2, USB PD 3
Analizador de Protocolo III : DALI, MDIO, MIPI RFFE 3, Modbus, PMBus, Profibus, PWM, SMBus, USB1.1
Analizador de Protocolo IV : eSPI, MII, RGMII, RMII, SVID
Logic Analyzer (LA) Mode
-
Capture digital waveforms and support bus decodes. Able to stack with a DSO to form as an MSO.
-
Provides multiple storage modes, users could select to have long time recording or precision acquisition.
-
Long Time Record: Transitional Storage VS Compressed Storage
For signal capture and analysis, usually require to record the signal for a long time. If the data is stored in a compressed way, it will cause your software to lag or even stop functioning when decompressing the data after it is sent back to the computer. Because PC memory size might insufficient for decompressed data size. To satisfy the requirement of smooth software operation and long-term recording without missing any data, the storage method adopted by the Acute analyzer is transitional storage rather than compression. After returning to the PC software, it doesn"t need to do the decompression. The decoded results can be displayed while the analysis is finished.
Digital and Analog Waveform Settings
Each channel supports both digital and/or analog waveforms measurements, voltage resolution can be changed between 2 levels for all channels at the same time.
Flow chart bus triggers |
Power trigger for serial bus, 8-states flow chart setting with Counter/Timer |
Detail parameters for each states |
Stack With Other Vendors of Oscilloscope
|
Digital & Analog Signals From MSO and External DSO From Other Vendors | |
MSO Enables Digital & Analog Channels (Using the same channels) |
*[1]: Decode & Digital Signals;*[2]: MSO Analog Signals;*[3]: External DSO Signals |
Protocol Analyzer (PA) Mode
It is hardware decoding, may log protocol data very long time if without waveforms. Application timing: Preliminary protocol debug.
Protocol Analyzer | Protocol Logger | Protocol Monitor |
Show real-time protocol data. Application timing: massive protocol data with some idles in between. |
Like data logger, save massive data into SSD hard drive. Application timing: massive protocol data. |
Like dash cameras, record protocol data by the device’s memory only. Application timing: trigger event only happens in very long time. |
|
*Esta solución solo es aplicable a algunos modelos de MSO.
*La serie MSO2000+ admite el cascada de hasta 8 dispositivos (128 CH) para la medición de la secuencia de encendido.
Informe de Secuencia de Encendido (Formato HTML)
Información Adicional
Elementos incluidos:
- Unidad principal MSO2000
- Cable USB 3.0
- Cable de conexión
- Cable de extensión
- Pinzas
- Bolsa de transporte con cremallera
Requisitos del sistema:
- Puerto USB 3.0
- 8 GB de RAM en PC como mínimo, se recomiendan 16 GB
Sistemas operativos compatibles:
- Windows 7/8/10/11 (64-bit)