MSO2116B

$3,400.00

Logic Analyzer, Protocol Analyzer, Simple DSO

Compare

visamasteramerican expressdiscovershopify pay
SKU: MSO2116B
Availability : In Stock Pre order Out of stock
Categories: MSO2000 Series
Tags: MSO2000
Overview
Model
Channels
Sample Rate
Memory
Bus Trigger / Protocol Analyzer
Power Sequence Channels
MSO2008E
8 2GHz
2Gb I 8
MSO2116E
16 2GHz
4Gb
I, II 16
MSO2116B
16 2GHz
4Gb
I, II, III 16
MSO2216B
16 2GHz
8Gb
I, II, III, IV 16 (128 / 8 sets cascaded)

Datasheet [PDF]

Bus Decode : BiSS-C, CAN 2.0B/CAN FD, DP_Aux, eSPI, I²C, I²S, MIPI I3C, MII, Serial Flash, SPI, SVID, UART (RS232), USB PD 3, USB1.1, ... (100+)

Bus Trigger I : I2C, MIPI I3C 1.1, SPI, UART (RS232)
Bus Trigger II : BiSS-C, CAN2.0B/CAN FD, DP_Aux, HID over I2C, I2S, LIN2.2, MIPI SoundWire 1.2, SENT, USB PD 3
Bus Trigger III : DALI, LPC, MDIO, Mini/Micro LED, MIPI RFFE 3, MIPI SPMI 2.0, Modbus, PMBus, Profibus, SMBus, SVI2, USB1.1
Bus Trigger IV : eMMC 4.5, eSPI, MII, RGMII, RMII, SD 2.0 (SDIO 2.0), Serial Flash (SPI NAND), SVID

Protocol Analyzer I : I2C, MIPI I3C 1.1, SPI, UART (RS232)
Protocol Analyzer II : BiSS-C, CAN2.0B/CAN FD, DP_Aux, HID over I2C, I2S, LIN2.2, USB PD 3
Protocol Analyzer III : DALI, MDIO, MIPI RFFE 3, Modbus, PMBus, Profibus, PWM, SMBus, USB1.1
Protocol Analyzer IV : eSPI, MII, RGMII, RMII, SVID


Logic Analyzer Mode

Logic Analyzer (LA) Mode

  • Capture digital waveforms and support bus decodes. Able to stack with a DSO to form as an MSO.

  •  Provides multiple storage modes, users could select to have long time recording or precision acquisition.

    •  Long Time Record: Transitional Storage VS Compressed Storage

    For signal capture and analysis, usually require to record the signal for a long time. If the data is stored in a compressed way, it will cause your software to lag or even stop functioning when decompressing the data after it is sent back to the computer. Because PC memory size might insufficient for decompressed data size. To satisfy the requirement of smooth software operation and long-term recording without missing any data, the storage method adopted by the Acute analyzer is transitional storage rather than compression. After returning to the PC software, it doesn"t need to do the decompression. The decoded results can be displayed while the analysis is finished.

     

    Digital and Analog Waveform Settings
    Each channel supports both digital and/or analog waveforms measurements, voltage resolution can be changed between 2 levels for all channels at the same time.

    Flow chart bus triggers

    Power trigger for serial bus, 8-states flow chart setting with Counter/Timer

    Detail parameters for each states

    Stack With Other Vendors of Oscilloscope
    Digital & Analog Signals From MSO and External DSO From Other Vendors
    MSO Enables Digital & Analog Channels
    (Using the same channels)
    *[1]: Decode & Digital Signals*[2]: MSO Analog Signals*[3]: External DSO Signals
    Protocol Analyzer Mode

    Protocol Analyzer (PA) Mode
    It is hardware decoding, may log protocol data very long time if without waveforms. Application timing: Preliminary protocol debug.

    Protocol Analyzer Protocol Logger Protocol Monitor
    Show real-time protocol data.
    Application timing: massive protocol data with some idles in between.
    Like data logger, save massive data into SSD hard drive.
    Application timing: massive protocol data.
    Like dash cameras, record protocol data by the device’s memory only.
    Application timing: trigger event only happens in very long time.
      Power Sequencing Verification
      Power Sequence Verification
      *This solution is only applicable to some MSO models.
      *MSO2000+ series supports cascading up to 8 devices(128 CH) for power sequence measurement.


      Power Sequence Report(HTML Format)

      Additional Information

      What's Included
      Included Items:
      • MSO2000 Main unit
      • USB 3.0 Cable
      • Lead Cable
      • Stack Cable
      • Grippers
      • Zippered Carrying Bag
      Software & Support

      Manual:

      MSO2000 Manual

      Download

      Software:

      Acute USB 3.0 Driver

      Download

      Acute MSO2000 Main Program

      Download

      Acute MSO2000 SDK - AqLaVISA

      Download

      System Requirements
      System Requirements:
      • USB 3.0 port
      • 8GB PC RAM (min), 16GB (recommended)
      Supported Operating Systems:
      • Windows 7/8/10/11 (64-bit)