TB3016B

$840.00

Analizador Lógico, Analizador de Protocolo, Osciloscopio Digital Sencillo DSO

Comparar

visamasteramerican expressdiscovershopify pay
SKU: TB3016B
Disponibilidad: En stock Reservar Agotado
Categorias: Serie TravelBus
Etiquetas: TravelBus
Descripción general
Modelo
Canales
Módulos
Decodificación de protocolo
Disparador de protocolo
TB3016F 19
I
70+
I
TB3016E 19
I, II
70+ I, II
TB3016B 25
I, II, III
70+

I, II, III

 

Decodificación de Protocolo: CAN FD, DALI2.0, DP_Aux, I²C, I²S, LIN2.2, PMBus, PWM, SMBus, SPI, MIPI I3C 1.1, UART, USB PD 3, ... (70+ decodes)

Módulo I: I²C, RS232, SPI
Módulos II: HID over I²C, I²S, LIN2.2, MDIO, PMBus, SMBus, USB1.1
Módulos III: BiSS-C, CAN2.0B, CAN-FD, DALI2.0, Modbus, Profibus, RS422, RS485, USB PD 3, ...
  • Canales diferenciales: 2 (CAN2.0B/CAN-FD), 4 (RS422/485)
  • Se puede usar con el Osciloscopio Acute TravelScope para formar un MSO
  • Toma a tierra: CAN2.0B/CAN-FD, RS485 (Aislamiento de seguridad >1000Vrms)
Modo Analizador Lógico

Logic Analyzer (LA) Mode

  • Capture digital waveforms and support bus decodes. Able to stack with a DSO to form as an MSO.

  •  Provides multiple storage modes, users could select to have long time recording or precision acquisition.

    •  Long Time Record: Transitional Storage VS Compressed Storage

    For signal capture and analysis, usually require to record the signal for a long time. If the data is stored in a compressed way, it will cause your software to lag or even stop functioning when decompressing the data after it is sent back to the computer. Because PC memory size might insufficient for decompressed data size. To satisfy the requirement of smooth software operation and long-term recording without missing any data, the storage method adopted by the Acute analyzer is transitional storage rather than compression. After returning to the PC software, it doesn"t need to do the decompression. The decoded results can be displayed while the analysis is finished.

     

    Flow chart bus triggers

    Power trigger for serial bus, 8-states flow chart setting with Counter/Timer

    Detail parameters for each states

    Waveform
    Modo Analizador de Protocolos

    Protocol Analyzer (PA) Mode
    It is hardware decoding, may log protocol data very long time if without waveforms. Application timing: Preliminary protocol debug.

    Protocol Analyzer Protocol Logger Protocol Monitor
    Show real-time protocol data.
    Application timing: massive protocol data with some idles in between.
    Like data logger, save massive data into SSD hard drive.
    Application timing: massive protocol data.
    Like dash cameras, record protocol data by the device’s memory only.
    Application timing: trigger event only happens in very long time.

      Información Adicional

      ¿Qué está incluido?
      Elementos incluidos:
      • Unidad principal TB3000
      • Cable USB 3.0
      • Cable de conexión
      • Pinzas
      • Bloque de terminales (Solo TB3016B)
      • Conector D-Sub (Solo TB3016B)
      Software y Soporte

      Manual:

      Manual TB3000

      Descargar

      Software:

      Controlador USB 3.0 de Acute

      Descargar

      Programa Principal de Acute TB3000

      Descargar

      Requisitos del sistema
      Requisitos del sistema:
      • Puerto USB 3.0
      • 8 GB de RAM en PC como mínimo, se recomiendan 16 GB
      Sistemas operativos compatibles:
      • Windows 7/8/10/11 (64-bit)