SVI3 Protocolos suportados

Alimentação

AMD Serial VID Interface 3

O que é SVI3?

SVI3 (Serial VID Interface 3) is AMD's proprietary serial bus protocol for communication between AMD processors and voltage regulator modules (VRMs). SVI3 uses three signals — SVC (clock), SVD (data), and SVT (telemetry) — to manage dynamic voltage and frequency scaling. The protocol enables the processor to command voltage changes, read VRM telemetry (current, temperature), and manage power states. SVI3 operates at clock speeds up to 50 MHz with a voltage range of 1.08V to 1.98V, and includes features for fast transient response and power state management that are critical for AMD Ryzen and EPYC processor platforms. Acute decoders cover SVI3 Rev. 1.01 and Rev. 2.0. Engineers debugging AMD power delivery systems need SVI3 decode to verify voltage requests, telemetry accuracy, and VRM response timing.

SVI3 Referência rápida

type Serial, synchronous
signals SVC, SVD, SVT (3 wires)
max Speed Up to 50 MHz
voltage Range 1.08V – 1.98V
standard AMD SVI3 Rev. 1.01, Rev. 2.0

Aviso importante

SVI3 protocol support is available only on the MSO2216B, MSO3124H, and MSO3124V. SVI3 decoding is provided to end customers upon request, and only to users who have been approved by AMD.

Instrumentos Acute compatíveis com SVI3

Soluções recomendadas

Recomendado para decodificação

MSO3124H

MSO3124H

Com canais analógicos

MSO3124H

MSO3124H

Todos os produtos compatíveis

Decodificação de protocolo
Disparo por hardware
Emulador de protocolo

Série MSO2000

Série MSO3000

Pronto para analisar este protocolo?

Veja como os instrumentos Acute capturam e decodificam este protocolo em tempo real. Solicite uma demo ou entre em contato com nossa equipe.

Como analisar SVI3 com instrumentos Acute

1

Conecte seu analisador lógico Acute aos sinais SVI3 SVC, SVD e SVT entre o processador AMD e o regulador de tensão.

2

Conecte um fio terra a referência de terra da placa alvo.

3

No software Acute, selecione o SVI3 protocol decoder e atribua SVC, SVD e SVT aos canais de entrada correspondentes.

4

Configure o decodificador para expected bus speed and protocol version.

5

Capture e visualize os SVI3 transactions showing voltage ID commands, telemetry readbacks, and power state transitions.

Perguntas frequentes

Qual taxa de amostragem e necessária para a análise SVI3 ?
SVI3 operates at clock speeds from 5 MHz to 50 MHz. For reliable decoding at the maximum 50 MHz clock, use a sample rate of at least 200 MHz (approximately 4x the clock). A sample rate of 400 MHz or higher is recommended to clearly resolve the clock-data relationship and accurately decode command and telemetry phases on the SVD and SVT lines.
Por que meu decodificador SVI3 mostra valores de ID de tensão incorretos?
Incorrect VID decoding is usually caused by misassigned signal channels — SVC, SVD, and SVT must be connected to the correct analyzer inputs. SVI3 also uses specific framing and timing that differs from Intel SVID. Verify that the decoder is configured for SVI3 (not SVID), and confirm the signal voltage threshold is appropriate for the SVI3 levels used on your platform (1.08V-1.98V). Acute supports SVI3 Rev. 1.01 and Rev. 2.0 — confirm your decoder is set to the correct revision for your platform.
Quantos canais são necessários para a análise de SVI3 ?
SVI3 requires 3 channels: SVC (clock), SVD (data), and SVT (telemetry). AMD platforms often have separate SVI3 buses for different power rails (e.g., core VDD, SoC VDD), so allocate 3 channels per SVI3 bus. Monitoring all power domains on an EPYC platform may require 6-9 channels for SVI3 alone.

Protocolos relacionados

Precisa de ajuda para escolher o instrumento certo para o seu protocolo? Entre em contato com nossa equipe de engenharia.