TDM Protocolos suportados

Áudio

Time Division Multiplexing

O que é TDM?

TDM (Time Division Multiplexing) is a multi-channel áudio transport scheme that carries multiple áudio channels on a single serial data line by assigning each channel to a specific time slot within a repeating frame. TDM is used in professional áudio systems, telecommunications equipment, áudio DSP arrays, and multi-codec architectures where more than two áudio channels must share a bus. The interface typically uses CLK, SYNC (frame sync), and one or more DATA lines, with frame sizes ranging from 2 to 32 or more time slots. Engineers debugging TDM buses need to verify time-slot assignments, frame sync alignment, clock accuracy, and data integrity across all active channels.

TDM Referência rápida

type Serial, synchronous
signals CLK, SYNC, DATA
max Speed Up to 24.576 MHz
voltage Range 1.8V – 3.3V
features Multi-channel audio

Instrumentos Acute compatíveis com TDM

Soluções recomendadas

Recomendado para decodificação

TB3016F

TB3016F

Com canais analógicos

MSO2116E

MSO2116E

Todos os produtos compatíveis

Pronto para analisar este protocolo?

Veja como os instrumentos Acute capturam e decodificam este protocolo em tempo real. Solicite uma demo ou entre em contato com nossa equipe.

Como analisar TDM com instrumentos Acute

1

Conecte seu analisador lógico Acute as linhas TDM CLK, SYNC e DATA.

2

Conecte um fio terra a referência de terra da placa alvo.

3

No software Acute, selecione o TDM protocol decoder e atribua cada sinal ao canal de entrada correspondente.

4

Configure o número de time slots per frame, bit depth per slot, and frame sync polarity.

5

Capture e visualize os áudio data for each time slot, verifying correct channel-to-slot mapping and frame alignment.

Perguntas frequentes

Qual taxa de amostragem e necessária para a análise TDM ?
TDM bit clocks can be high — a 32-slot, 32-bit, 48 kHz TDM frame requires a 49.152 MHz bit clock. Sample at a minimum of 4x the TDM bit clock frequency. For a 24.576 MHz clock, use at least 100 MHz sampling. os analisadores lógicos Acute with up to 2 GHz timing analysis handle even the fastest TDM configurations.
Por que alguns slots de tempo TDM mostram dados de áudio incorretos ou ausentes?
Incorrect slot data usually indicates a frame sync misalignment or an incorrect slot count configuration in either the decoder or the hardware. If the frame sync edge is not aligned with the expected first bit of slot 0, all subsequent slot boundaries will be shifted. Verify the frame sync polarity and delay settings, and confirm that both the transmitter and receiver agree on the number of slots and bits per slot.
Quantos canais são necessários para a análise de TDM ?
TDM requires a minimum of 3 channels: CLK, SYNC, and DATA. If your design uses multiple data lines (e.g., one for each direction or to double the slot count), add one channel per additional data line. Most TDM configurations can be fully analyzed with 3 to 5 logic analyzer channels.

Protocolos relacionados

Precisa de ajuda para escolher o instrumento certo para o seu protocolo? Entre em contato com nossa equipe de engenharia.