TL4234B

$3,400.00

Logic Analyzer, Protocol Analyzer, Simple DSO

Compare

visamasteramerican expressdiscovershopify pay
SKU: TL4234B
Availability : In Stock Pre order Out of stock
Categories: TravelLogic Series
Overview
Model
Channels
Sample Rate
Memory
Bus Trigger
Protocol Analyzer
TL4134E 34
2GHz
4Gb
I I
TL4134B 34
2GHz
4Gb
I, II I, II
TL4234B
34
2GHz 8Gb
I, II, III I, II, III

Bus Trigger I  : BiSS-C, CAN2.0B/CAN FD, DP_Aux, HID over I2C, I2C, I2S, LIN2.2, MIPI I3C 1.1, SPI, UART (RS232), USB PD 3.0

Bus Trigger II : DALI, LPC, Mini/Micro LED, PMBus, Profibus, SMBus, SVI2, USB1.1, ...

Bus Trigger III : eMMC 4.5, eSPI, MII, RGMII, RMII, NAND Flash, SD 3.0 (SDIO 2.0), ...

Protocol Analyzer I  : BiSS-C, CAN2.0B/CAN FD, DP_Aux, HID over I2C, I2C, I2S, LIN2.2, MIPI I3C 1.1, SPI, UART (RS232), USB PD 3.0

Protocol Analyzer II : DALI, Mini/Micro LED, Profibus, SMBus, USB1.1, ...

Protocol Analyzer III : eSPI, MII, RGMII, RMII, ...

Bus Decode : CAN 2.0B/CAN FD, DP_Aux, eMMC 4.5, eSPI, I2C, I2S, MIPI DSI LP, MIPI I3C 1.1, NAND Flash, Profibus, SD 3.0 (SDIO 2.0), SPI, UART (RS232), ... 100+

    Logic Analyzer Mode

    Logic Analyzer (LA) Mode

    • Capture digital waveforms and support bus decodes. Able to stack with a DSO to form as an MSO.

    •  Provides multiple storage modes, users could select to have long time recording or precision acquisition.

      •  Long Time Record: Transitional Storage VS Compressed Storage

      For signal capture and analysis, usually require to record the signal for a long time. If the data is stored in a compressed way, it will cause your software to lag or even stop functioning when decompressing the data after it is sent back to the computer. Because PC memory size might insufficient for decompressed data size. To satisfy the requirement of smooth software operation and long-term recording without missing any data, the storage method adopted by the Acute analyzer is transitional storage rather than compression. After returning to the PC software, it doesn"t need to do the decompression. The decoded results can be displayed while the analysis is finished.

       

      Flow chart bus triggers

      Power trigger for serial bus, 8-states flow chart setting with Counter/Timer

      Detail parameters for each states

      Stack With Other Vendors of Oscilloscope
      Protocol Analyzer Mode

      Protocol Analyzer (PA) Mode
      It is hardware decoding, may log protocol data very long time if without waveforms. Application timing: Preliminary protocol debug.

      Protocol Analyzer Protocol Logger Protocol Monitor
      Show real-time protocol data.
      Application timing: massive protocol data with some idles in between.
      Like data logger, save massive data into SSD hard drive.
      Application timing: massive protocol data.
      Like dash cameras, record protocol data by the device’s memory only.
      Application timing: trigger event only happens in very long time.

        Additional Information

        What's Included
        Included Items:
        • TL4000 Main unit
        • USB 3.0 Cable
        • 18.5cm Lead Cable
        • Stack Cable
        • Grippers
        • Zippered Carrying Case
        • 8.5cm Lead Cable (TL4234B Only)
        Software & Support

        Manual:

        TL4000 Manual

        Download

        Software:

        Acute USB 3.0 Driver

        Download

        Acute TL4000 Main Program

        Download

        Acute TL4000 SDK - C/C++

        Download

        Acute TL4000 SDK - C#

        Download

        System Requirements
        System Requirements:
        • USB 3.0 port
        • 8GB PC RAM (min), 16GB (recommended)
        Supported Operating Systems:
        • Windows 7/8/10/11 (64-bit)