LA4068E

$8,400.00

Logic Analyzer, Protocol Analyzer, Simple DSO

Compare

visamasteramerican expressdiscovershopify pay
SKU: LA4068E
Availability : In Stock Pre order Discontinued
Categories: LA4000 Series
Overview
 Model Channels Bus Triggers Protocol Analysis
LA4068E 68 I I
LA4068B 68 I, II I, II
LA4136E 136 I I
LA4136B 136 I, II I, II
LVDS POD


Protocol Decode : 10BASE-T1S¹, CAN 2.0B/CAN FD, DP_Aux¹, eMMC 4.5, I²C, MIPI I3C 1.1, SD 3.0, SPI, SVID², SWD, UART (RS232), USB1.1, USB PD 3... (100+)

Protocol Trigger I : 10BASE-T1S¹, I²C, MIPI I3C 1.1, SPI, UART (RS232), USB PD 3, ...

Protocol Trigger II : eMMC 4.5, eSPI, NAND Flash, SD3.0, Serial Flash, SVID³, ...

Protocol Analyzer I : 10BASE-T1S¹, CAN 2.0B/CAN FD, I²C, MIPI I3C 1.1, SPI, USB PD 3, ...

Protocol Analyzer II : DALI, eSPI, MDIO, PMBus, Profibus, PWM, SVID³, ...

    Logic Analyzer Mode

    Logic Analyzer (LA) Mode

    • Capture digital waveforms and support bus decodes. Able to stack with a DSO to form as an MSO.

    •  Provides multiple storage modes, users could select to have long time recording or precision acquisition.

      •  Long Time Record: Transitional Storage VS Compressed Storage

      For signal capture and analysis, usually require to record the signal for a long time. If the data is stored in a compressed way, it will cause your software to lag or even stop functioning when decompressing the data after it is sent back to the computer. Because PC memory size might insufficient for decompressed data size. To satisfy the requirement of smooth software operation and long-term recording without missing any data, the storage method adopted by the Acute analyzer is transitional storage rather than compression. After returning to the PC software, it doesn"t need to do the decompression. The decoded results can be displayed while the analysis is finished.

       

      Parallel Clause Triggers
      16-States parallel IF Clause settings for 128/64 channel value compare combined with AND/OR logic condition and 4 Timer/Counter conditions.

       

      Flow chart bus triggers

      Power trigger for serial bus, 8-states flow chart setting with Counter/Timer

      Detail parameters for each states

      Stack With Other Vendors of Oscilloscope

      Waveform
      Protocol Analyzer Mode

      Protocol Analyzer (PA) Mode
      It is hardware decoding, may log protocol data very long time if without waveforms. Application timing: Preliminary protocol debug.

      Protocol Analyzer Protocol Logger Protocol Monitor
      Show real-time protocol data.
      Application timing: massive protocol data with some idles in between.
      Like data logger, save massive data into SSD hard drive.
      Application timing: massive protocol data.
      Like dash cameras, record protocol data by the device’s memory only.
      Application timing: trigger event only happens in very long time.
      Protocol Analyzer Protocol Logger Protocol Monitor

      Additional Information

      What's Included
      Included Items:
      • LA4000 Main unit
      • LA-Pod
      • USB 3.0 Cable
      • Flying Lead Cable
      • BNC to MCX
      • Grippers
      • Adapter / Power cord
      Software & Support

      Manual:

      LA4000+ Manual

      Download

      BusFinder & Logic Analyzer

      Download

      Software:

      Acute USB 3.0 Driver

      Download

      Acute Logic Analyzer Main Program

      Download

      System Requirements
      System Requirements:
      • USB 3.0 port
      • 8GB PC RAM (min), 16GB (recommended)
      Supported Operating Systems:
      • Windows 7/8/10/11 (64-bit)